Optical fibre Fabry-Pérot interferometer based on inline microcavities for salinity and temperature sensing (2024)

Introduction

Salinity is a fundamental parameter and indicator of water quality, due to the effects it has on human health and other living organisms, with a large impact on the equilibrium of ecosystems. Commercially available solutions for measuring salinity are typically based on conductivity measurements. However, these systems are not immune to electromagnetic interference. In addition, the refractive index correlates to salinity better than conductivity1,2. Thus, optical fibre-based detection of salinity is a promising alternative offering many advantages such as immunity to electromagnetic interference, deployability, distributed and remote sensing, environmental friendliness, and cost-effectiveness3. Optical fibre-sensors for salinity find applications in varied environments, from industrial processes such as desalination plants, to marine environment. The in situ detection of salinity in marine environments through optical fibre probes has been demonstrated by several authors2,4,5.

Optical fibre-based sensors for salinity detection based on intrinsic refractive index (RI) changes include etched fibre-Bragg gratings4, surface plasmon resonance6, tapered optical fibres7, two-core fibres8, panda fibres9, and Fabry-Pérot (FP) interferometers10. For these sensing configurations, there is a trade-off between sensitivity and mechanical strength. Slight increases of the sensitivity have been demonstrated but at the cost of the sensor’s response time or mechanical strength. A good candidate to overcome such issues are interferometric sensors based on hollow cavities, in which the optical cavity is fabricated within the optical fibre. Hollow cavities within the optical fibre are typically fabricated by focused ion beam10, femtosecond laser ablation11, and chemical etching12. However, these techniques required either a long fabrication time, or complex fabrication processes. One other technique forthe fabrication of hollow cavities, which has been growing in popularity, is throughfusion splicing13, a low-cost and simple fabrication process, where the length of the cavity can easily be controlled by tailoring the fusion splicing parameters. Variations of this fabrication process consist in preconditioning the fibres tips, either with a liquid14, by arc discharge15, or employing a silica capillary tube16. Although these structures consist of hollow cavities within the fibres, they are mechanically strong, being resistant to lateral loads17 and strain16. These type of sensors can also withstand high temperatures since no film or polymer integrate the sensors structure18.

The salinity sensors developed in this work are based on optical fibre sensing elements consisting of optical cavities within the fibres. The cavities act as FP interferometers rendering the presence of a certain refractive index, which is detectable by a phase change of the interferometric response caused by the change of the optical path length of the cavity19. Employing single mode (SMF28e + , Corning) and multimode graded index fibres (GIF625, Thorlabs), a novel method for the fabrication of FP cavities within the optical fibre is presented, combining chemical etching and fusion splicing for the formation of a hollow cavity. The use of such structures as salinity sensors is demonstrated resulting in a sensitivity of 12.09 nm/M.

Vernier-effect based sensors have been demonstrated and applied to optical fibre-based FP sensors for measurement of strain, magnetic field and temperature20,21. Here, a configuration based on the Vernier effect is reported for salinity and temperature sensing. Such configuration is composed by a sensing FP along with a reference FP, which leads to a magnification of the sensitivity to salinity changes, where sensitivities as high as 82.61 nm/M are experimentally demonstrated, with the added advantage of measuring simultaneously temperature and salinity changes.

Structure of the Sensors and Principle of Operation

Individual configuration

The fundamental sensing element consists of an individual air bubble fabricated in-between a section of single mode fibre (SMF) and graded index multimode fibre (GIF), as represented in Fig.1(a). The hollow cavity is fabricated by a combination of hydrofluoric acid (HF) etching and fusion splicing, with ion milled microfluidic channels linking it to the surrounding medium.

(a) Schematic of the sensing FP in single configuration, consisting of a single micro-bubble fabricated in-between the SMF28e+ and GIF625 fibres. (b) Schematic of the Vernier sensor: two cavities are employed and their spectra combined, where one is the sensing element and the other acts as a reference by being kept within a reference medium.

Full size image

The cavity acts as an FP interferometer, i.e., a cavity between two parallel reflective surfaces, where the reflective surfaces consist of the fiber-cavity interfaces. At the first interface, a fraction of the incident light is reflected while the remaining goes through it, propagating inside the cavity, and reaching the second surface. At this surface, part of the light is transmitted but another is reflected back onto the cavity, which will again propagate inside the cavity till it reaches the other surface, and then it reflects back again, and so on and so forth. The light rays inside the cavity interfere with each other depending on their relative path difference, so only certain frequencies are supported by the cavity. Consequently, the transmission and reflection spectra of an FP interferometer are composed of resonances whose spectral position depends on the optical path length of the cavity. In a round-trip in the FP interferometer, the phase difference (δ) between two waves is

$$\delta =\frac{4\,\pi \,n\,L}{\lambda }$$

(1)

where n is the effective RI of the mode propagating inside the cavity, L is the length of the cavity, and λ is the vacuum wavelength of the incident light. As such, the reflection spectrum (R) of an FP interferometer can be described by

$$R\propto 1-\frac{1}{1+F\,{\sin }^{2}(\delta /2)}$$

(2)

where F is the finesse coefficient. This coefficient is given by the following expression:

$$F=\frac{4\,{R}_{mirror}}{1+F\,{si}{{n}}^{2}(\delta /2)}$$

(3)

where Rmirror is the mirror reflection coefficient. From 3D-finite difference time domain simulations, the reflection coefficients of the fiber-cavity interfaces are approximately 3% at a wavelength of 1550 nm. Due to the low reflectivity value, the cavity acts as a low-finesse FP. Therefore, the FP can be described by a two-wave interferometer and, in this case, the reflection spectrum of the FP interferometer can be simply described by

$$R=A\,\cos (\frac{4\,\pi \,n\,L}{\lambda })$$

(4)

where A is the amplitude of the reflection spectrum.

By changing either the refractive index of the cavity, the resonances will shift. It is based on this principle that the interrogation and determination of salinity is possible using an FP interferometer: when the salinity varies, so does the RI, leading to a change in the optical length of the cavity which induces a shift of the fringes position.

Vernier configuration

In the Vernier configuration, depicted in Fig.1(b), the system is composed of a sensing FP and a reference FP, where the optical output of the two cavities is combined by an optical fibre circulator.

The sensing cavity is filled with the saline solution while the reference cavity is kept in air, acting as a reference medium with a constant RI. The cavities are designed to have slightly different optical lengths, and therefore have different free spectral ranges (FSRs), thus originating the so-called Vernier effect.

Through the Vernier effect, the sensitivity of a device is magnified. When the output of two mismatched interferometers is combined, the resulting spectrum consists of a series of resonances with different amplitudes. The amplitude modulation, or envelope, of the spectrum is a periodic signal with peaks and dips whose spectral position depend on the optical length of the composing cavities. When the optical length of the sensing cavity changes, the shift of the envelope, when compared to the spectral shift of the individual cavity, is magnified by a factor M due to the Vernier effect. The optical length change can be due to either a change in the physical length of the cavity or a change of the refractive index within the cavity.

Sensors that employ the Vernier effect can operate in two regimes. In the first regime, the free spectral range difference between the two resonators is large compared to the full width half maximum of the peaks of the individual interferometers, which originates the typical comb like spectrum. However, this regime has a limitation because the minimum detectable shift is equal to the free spectral range (FSR) of the individual sensor22. In the second regime, the FSR difference is smaller than the full width half maximum of the resonances of the individual interferometer. In this regime, a periodic envelope signal modulates the output of the sensor, overcoming the limitation of the sensors operating in the first regime23,24. The FP cavities employed in this work have low-finesse and small detune in terms of FSRs, therefore operating in the second regime.

So, when the output spectra of the two cavities with different optical lengths are added, the envelope of the reflection spectrum can be expressed by

$${R}_{E}=2\,A\,\cos (\frac{4\,\pi \,({n}_{R}\,{{\rm{L}}}_{R}-{n}_{S}{L}_{S})}{\lambda })$$

(5)

where LR and LS are the lengths of the reference and sensing cavities, and nR and nS are the refractive indices of the reference and sensing cavities, respectively. The period of RE is23:

$$FS{R}_{E}=\frac{FS{R}_{R}\,FS{R}_{S}}{|FS{R}_{R}-FS{R}_{S}|}$$

(6)

where FSRR is the free spectral range of the reference cavity, and FSRS is the free spectral range of the sensing cavity. In such configuration, when there is a shift Δ(nL)S inthe sensing element, the shift of the sensor comprised by the sensing and reference FPs is magnified by a factor M23:

$$M=\frac{FS{R}_{R}}{|FS{R}_{R}-FS{R}_{S}|}$$

(7)

So, in comparison with a single sensing element, the sensitivity of the system composed by the sensing and reference elements will increase by a M-fold factor, as a small shift of the resonance wavelengths of the sensing interferometer will result in a much larger shift of the spectrum of the combined cavities. In addition, the Vernier configuration enables the simultaneous measurement of temperature and salinity, because the analysis can be performed by trackingboth the shift of the envelope and the shift of the individual fringes.

Fabrication Process

The formation of bubbles during fibre splicing is considered undesired in most applications since it creates a hollow cavity inside the fibre, which interrupts the fibre core and perturbs the transmission of the light. Bubble formation is usually due to a poor fibre profile (typically a poor cleave) or a fusion current that is too high. In this novel fabrication process presented here, the micro-bubble within the fibre is created by making use of both: first, a small cavity is etched by HF in a GIF, and then, the cavity is enlarged by fusion splicing the GIF to a SMF.

The first step of the fabrication process is the cleaving of the multimode graded index fibre tips (GIF625, Thorlabs), witha 62.5 μm core diameter and a numerical aperture of 0.275, which is then etched for 5 minutes in 9.6% HF gel, creating a shallow cavity in the fibre tip at an etch rate of 750 nm/min. The 9.6% HF buffered gel formulation, commonly used in dentistry as porcelain etchant gel, has a reduced etch rate compared to buffered hydrofluoric acid based etchants, providing better control of the etching depth and beingat the same time safer to handle25,26.

Using a Fujikura 70 S splicer, the etched fibre tip is spliced to a cleaved single mode fiber (SMF28e+, Corning) employing the splicing parameters summarized in Table1 that have been optimized to promote the formation of a hollow cavity during the splicing step. The fusion power is a key parameter in order to avoid unsuccessful micro-bubbles formation as depicted in Fig.2(a,b): when the power is too low the bubble is not generated and only the small HF cavity is present; when the power is too high the bubble becomes too wide with thin fragile walls. Regarding the HF etching step, and as can be seen in Fig.2(c), when no etching is performed in the fibre tip the micro-bubble does not form. Anoptical image ofa micro-bubble successfully fabricated by the combined HF-fusion splicing process is shown in Fig.2(d). The length of the micro-bubble can be controlled by changing the HF etching time: the length of the micro-bubbles is inversely proportional to the etching time, where cavities with lengths between 80 µm and 115 µm have been obtained. The sensing and reference cavities that are experimentally tested are 90 ± 3 μm and 102 ± 3 μm long, respectively, for an HF etching time of 5 and 2 minutes, respectively.

Full size table

Top - Optical images of non-successful cavities formation due to (a) too low current, (b) excessively high current, and (c) no prior HF etch. Bottom - Images of hollow cavities fabricated by the hybrid method HF etch-fusion splicing: (d) optical microscope, and (e) scanning electron microscope.

Full size image

The microfluidic access channels are obtained by focused ion beam milling and are roughly located in the centre of the cavity, which is easily located in the SEM as a bulge in the fibre next to the splice line. Two 15 × 15 μm2 channels are milled diametrically opposed to each other and their location is chosen to be roughly in the centre of the bubble, as shown in Fig.2(e). The milling parameters are: I = 65 nA, V = 30 kV, resulting in a total milling time of approximately 8 minutes.

Results and Discussion

Methodology

The light is injected into the sensors by a broadband light test source (ASE730, Thorlabs), which operates in the wavelength range extending from 1530 nm to 1610 nm, while the output spectra are collected by an optical spectrum analyser (AQ6370C, Yokogawa). The use of an optical fibre circulator (6015-3-FC, Thorlabs) enables the measurement of the reflection outputs of the tested sensors. In Fig.3 is depicted a schematic of the experimental setup for characterization of the Vernier-based sensor composed by the sensing and reference FPs. For the characterization of the individual configuration, i.e., the sensing architecture with no reference FP, the reference arm is disconnected.

Schematic of the experimental setup.

Full size image

To experimentally characterize the sensors sensitivity to salinity, the output of each sensor is acquired while the sensor is dipped in solutions with different salinity values. The aqueous solutions are prepared by dissolving sodium chloride, NaCl, in deionized (DI) water. The set of tested saline solutions has molar concentrations ranging from 0 M to 0.297 M, equivalent to a RI interval from 1.3176 to 1.3212.

For the experimental characterization of the sensors, a relatively large volume of solution is used to ensure that the salinity values do not vary in the cavity region as a consequence of evaporation of the aqueous solution throughout the procedure.

To avoid any cross-contamination between solutions of different salinity levels, the sensors are flushed with DI water in-between measurements. In addition, DI water is also used as a baseline to determine the wavelength shifts induced by the tested saline solutions. It is observed that for each cycle of flushing the sensors always recover to their baseline, proving the repeatability of the sensor. The recovery time is within three consecutive scans of the optical spectrum analyser, corresponding to approximately 15 seconds, which is a response time compatible with the possible application of these sensors.

The responsivity of the sensors to temperature changes is evaluated by dipping the sensors in a bath of DI water, whose temperature is regulated by a hot plate while the temperature reading values are recorded by a submerged digital thermometer.

Given that the FP sensing cavities are typically sensitive to axial strain and displacement, and in order to avoid cross-sensitivity, the sensors are immobilized with epoxy glue in a prototyped holder.

Refractive index as a function of salinity

To establish the conversion between the RI values and salinity of the tested saline solutions at 1550 nm, it is necessary to resort to media of known RI at the wavelength of interest. Cargille refractive index liquids (Cargille Laboratories) have been selected, as these are very stable liquids with known RI values. An individual sensing FP is dipped in each of the two selected Cargille liquids, with RI of 1.315 and 1.320 at 1550 nm, respectively, from which the linear dependency of the dip’s spectral position as a function of RI can be obtained. The same sensing FP is also dipped in DI water (0 M) and a saline solution of 0.339 M, from which the dip position dependency on the salinity is extracted. The resonant dips in the region of 1550 nm for the tested liquids and saline solutions are shown in Fig.4(a). The linear dependencies of the dip position as a function of salinity and as a function of RI, extracted from Fig.4(b), are given by the following Equations:

$${\lambda }_{R}(S)=12.46\,n+1547.55$$

(8)

$${\lambda }_{R}(n)=1031.00\,n+189.11$$

(9)

where λR is the resonant wavelength in nm, n is the RI in RIU, and S is the salinity in M. In the region of 1550 nm and from the Equations (8,9), the relation between RI and salinity is given by

$$n\,(S)=\frac{12.45976\cdot {\rm{S}}-189.11}{1031.00}$$

(10)

Resonant dips of the output spectrum of a single cavity dipped in two Cargille liquids with RI of 1.315 and 1.320 at 1550 nm, and in two saline solutions with salinity of 0 M and 0.339 M. (a) Detail of the output spectrum around 1550 nm. (b) Plot of the dip wavelengthposition as a function of RI, for the Cargille liquids, and salinity, for the saline solutions.

Full size image

Single configuration

The output spectra of the individual sensing FP for three different salinity values are plotted in Fig.5(a). An individual spectrum consists of a set of interference fringes on the form of a sinusoidal wave, which is in good-agreement with a low-reflectivity FP interferometer, and therefore the output spectrum is similar to that of a two-wave interferometer.

(a) Output spectra of a sensing FP in single configuration when immersed in three solutions of different salinity. Resonant wavelength shift at around 1550 nm of a single sensing cavity as a function of(b) salinity and (c) temperature shift.

Full size image

When immersed in saline solutions of increasing salinity the resonant peaks of the sensing FP shift towards larger wavelengths, which is concordant with the increase of RI when the salinity increases.

The sensor’s sensitivity to salinity is interrogated by tracking the shift of the resonant wavelength. In Fig.5(b), the shift of one of resonances at around 1550 nm is plotted as a function of the molarity of the saline solutions. A total shift of 3.56 nm is obtained for the salinity range from 0 M to 0.297 M. The sensitivity is obtained from a linear fit to the experimental data, yielding a value of 12.09 ± 0.20 nm/M with an R2 of 0.9978, for the single-FP configuration. Using the previously established conversion between RI and salinity, the resulting sensitivity to RI changes is 999.6 ± 16.5 nm/RIU.

The limit of detection of the sensor is extracted by acquiring 15 output spectra in series and then determining the variance of the position of the resonant wavelengths. The 3-sigma limit of detection, LOD, is 2.1 × 10−3 M.

Regarding the temperature dependence of the sensor, which is plotted in Fig.5(c), a total shift of −0.96 nm is obtained for a temperature shift of 8.3 °C (ranging from 21.7 °C to 30 °C). The sensitivity to temperature of the sensing FP is −115.3 ± 0.9 pm/°C, with an R2 of 0.9993, where the negative sign of the sensitivity arises from the negative thermo-optic coefficient of the water. The factor of 10−4 from the temperature to salinity sensitivities ratio is consistent with the thermo-optic coefficient of the water reported in the literature, in the order of 10−4 RIU/°C27. This sensor’s cross-sensitivity to temperature is very low because the temperature’s sensitivity is much lower than the sensitivity to salinity changes. However, in such configuration the simultaneous measurement of temperature and salinity shifts is not possible which have led to the development of the following configuration.

Vernier configuration

The characterized system is composed by the sensing FP, previously characterized in individual configuration, and a reference FP kept in air. The output of the sensor is plotted in Fig.6(a), and it is composed by a set of interference fringes with modulated amplitude due to the difference of optical path lengths between the sensing and reference FPs. As described previously, the amplitude modulation, or envelope, is a function of the optical length of the cavities that comprise the system, and therefore its peaks position depends on the salinity and temperature of medium within the sensing cavity.

(a) Output spectra of the Vernier-configuration sensor comprised by the sensing and reference FPs in DI water (0 M) and in 0.217 M saline solution. Resonant wavelength shifts of the system comprised by the sensing and reference FPs as a function of (b)salinity and (c) temperature shift.

Full size image

The shift of the envelope’s peak, ΔλEnvelope, as a function of the salinity level is plotted in Fig.6(b), yielding a very high sensitivity to salinity changes of 82.61 ± 1.14 nm/M, or 6830.0 ± 94.3 nm/RIU, with an R2 of 0.9987, which is one of the highest sensitivities to salinity experimentally demonstrated by an optical fibre probe, to the best of the authors knowledge. The LOD for this sensor is 3.6 × 10−3 M.

The obtained sensitivity is 6.83-fold higher than the sensitivity of thesensing FP in single-configuration, 12.09 ± 0.20 nm/M, which demonstrates the magnification enabled by the Vernier configuration. For the cavities that compose this system, the expected analytical magnification given by Equation (7) is M = 7.14. The small discrepancy between magnification factors is justified by the uncertainty in the cavities length and in the RI of water. In theory, the detune in the FPs lengths could be designed to achieve a magnification factor as high as desired, but in practice that factor is limited because the envelope period cannot be larger than the wavelength range of both the light source and the optical spectrum analyser. Regarding the temperature effect, a sensitivity of −587.37 ± 0.01 pm/°C is obtained from Fig.6(c) with an R2 of 0.9962.

Analysing the shift of the peak of the output spectra, the obtained sensitivity to salinity shifts is 13.91 ± 0.29 nm/M, or 1150.0 ± 24.0 nm/RIU, with an R2 of 0.9969, and to temperature changes is −0.0775 ± 0.0021 pm/°C, with an R2 of 0.9945.

Sensitivity matrix for simultaneous measurement of temperature and salinity

For in situ sensing of salinity, the system needs to discriminate between temperature and salinity induced shifts, even when the sensitivity of the system to temperature shifts is much smaller than its sensitivity to salinity changes. As such, the system needs to be interrogated using two different methods, each yielding different sensitivities. As described previously, one of the methods consists in analysing the shift of the envelope of the output spectrum of the system, ΔλEnvelope, and the other method is based on the shift of the individual fringes of the output spectrum, ΔλPeak. The wavelength shifts of the system’s output can be described as a function of salinity and temperature changes by

$$[\begin{array}{c}{\rm{\Delta }}{\lambda }_{Envelope}\\ {\rm{\Delta }}{\lambda }_{Peak}\end{array}]=[\begin{array}{cc}{S}_{Env,S} & {S}_{Env,T}\\ {S}_{Peak,S} & {S}_{Peak,T}\end{array}]\,[\begin{array}{c}{\rm{\Delta }}S\\ {\rm{\Delta }}T\end{array}]$$

(11)

where ΔS and ΔT are the water salinity and temperature variations, respectively. The matrix’s parameters Sm,n, where m = Envelope or Peak, and n = Salinity (S) or Temperature (T), are the sensitivity coefficients obtained from the linear fits to the experimentally measured wavelength shiftsreportedin the previous section.

Inverting the matrix in Equation (11), the salinity and temperature shifts for the Vernier-configuration sensor are given by

$$[\begin{array}{c}{\rm{\Delta }}S\\ {\rm{\Delta }}T\end{array}]=0.0686[\begin{array}{cc}-0.0775 & 0.5874\\ -13.9111 & 82.6097\end{array}]\,[\begin{array}{c}{\rm{\Delta }}{\lambda }_{Envelope}\\ {\rm{\Delta }}{\lambda }_{Peak}\end{array}]$$

(12)

where ΔS is in M, ΔT is in °C, and Δλ is in nanometres.

Conclusions

In conclusion, the detection of salinity through hollow cavities fabricated by HF etching and fusion splicing has been demonstrated, resulting in high sensitivities in comparison with other optical fibre-based sensors. The sensitivity can be further increased when these structures are used in Vernier-configuration, where one of the cavities is kept in a reference medium, yielding very large sensitivities up to 82.61 nm/M or 6830.0 nm/RIU. Also, such configuration allows the simultaneous measurement of salinity and temperature which is an extremely important feature for in situ detection. The innovative fabrication process of the cavities is fairly simple and low-cost and it is based on two simple steps, etching by the HF gel and fusion-splicing, comprising the application of standard single mode and multimode graded index fibres. The characterization of the sensors was performed in the range of salinity between 0 M to 0.297 M, which widely covers the range of salinity found in the nature, from lakes, seas and oceans. Moreover, and even though the characterization of the reported sensors was performed in reflection, these sensors can be employed in transmission mode without loss of generality.

Data Availability

The datasets generated during and/or analysed during the current study are available from the corresponding author on reasonable request.

Change history

References

  1. Millard, R. C. & Seaver, G. An index of refraction algorithm for seawater over temperature, pressure, salinity, density, and wavelength. Deep Sea Research Part A. Oceanographic Research Papers 37, 1909–1926 (1990).

    Article ADS Google Scholar

  2. Menn, M. L. et al. Advances in measuring ocean salinity with an optical sensor. Measurement Science and Technology 22, 115202 (2011).

  3. Qian, Y., Zhao, Y., Wu, Q. & Yang, Y. Review of salinity measurement technology based on optical fiber sensor. Sensors and Actuators B: Chemical 260, 86–105 (2018).

    Article CAS Google Scholar

  4. Pereira, D. A. & Frazao, O. Fiber Bragg grating sensing system for simultaneous measurement of salinity and temperature. Optical Engineering 43, 299–304 (2004).

    Article ADS Google Scholar

  5. Díaz-Herrera, N., Esteban, O., Navarrete, M. C., Haitre, M. L. & González-Cano, A. In situ salinity measurements in seawater with a fibre-optic probe. Measurement Science and Technology 17, 2227–2232 (2006).

    Article ADS Google Scholar

  6. Michel, D., Xiao, F. & Alameh, K. A compact, flexible fiber-optic Surface Plasmon Resonance sensor with changeable sensor chips. Sensors and Actuators B: Chemical 246, 258–261 (2017).

    Article CAS Google Scholar

  7. Rahman, H. A. et al. Tapered plastic multimode fiber sensor for salinity detection. Sensors and Actuators A: Physical 171, 219–222 (2011).

    Article CAS Google Scholar

  8. Guzman-Sepulveda, J. R., Ruiz-Perez, V. I., Torres-Cisneros, M., Sanchez-Mondragon, J. J. & May-Arrioja, D. A. Fiber Optic Sensor for High-Sensitivity Salinity Measurement. IEEE Photonics Technology Letters 25, 2323–2326 (2013).

    Article ADS Google Scholar

  9. Wang, X., Wang, J., Wang, S. S. & Liao, Y. P. Fiber-Optic Salinity Sensing With a Panda-Microfiber-Based Multimode Interferometer. Journal of Lightwave Technology 35, 5086–5091 (2017).

    Article ADS CAS Google Scholar

  10. Nguyen, L. V., Vasiliev, M. & Alameh, K. Three-Wave Fiber Fabry–Perot Interferometer for Simultaneous Measurement of Temperature and Water Salinity of Seawater. IEEE Photonics Technology Letters 23, 450–452 (2011).

    Article ADS Google Scholar

  11. Rao, Y.-J. et al. Micro Fabry-Perot interferometers in silica fibers machined by femtosecond laser. Optics Express 15, 14123–14128 (2007).

    Article ADS Google Scholar

  12. Coelho, L. et al. Simultaneous measurement of partial pressure of O 2 and CO 2 with a hybrid interferometer. Optics letters 37, 3063–3065 (2012).

    Article ADS CAS Google Scholar

  13. Jáuregui-Vázquez, D. et al. An All Fiber Intrinsic Fabry-Perot Interferometer Based on an Air-Microcavity. Sensors 13, 6355–6364 (2013).

    Article Google Scholar

  14. Liu, S. et al. High-sensitivity strain sensor based on in-fiber rectangular air bubble. Scientific Reports 5 (2015).

  15. Duan, D.-W., Rao, Y., Hou, Y.-S. & Zhu, T. Microbubble based fiber-optic Fabry–Perot interferometer formed by fusion splicing single-mode fibers for strain measurement. Applied optics 51, 1033–1036 (2012).

    Article ADS Google Scholar

  16. Monteiro, C., Silva, S. & Frazao, O. Hollow Microsphere Fabry–Perot Cavity for Sensing Applications. IEEE Photonics Technology Letters 29, 1229–1232 (2017).

    Article ADS CAS Google Scholar

  17. Novais, S., Ferreira, M. S. & Pinto, J. L. Lateral Load Sensing With an Optical Fiber Inline Microcavity. IEEE Photonics Technology Letters 29, 1502–1505 (2017).

    Article ADS CAS Google Scholar

  18. Li, Z. et al. Microbubble-based fiber-optic Fabry–Perot pressure sensor for high-temperature application. Applied Optics 57, 1738 (2018).

    Article ADS CAS Google Scholar

  19. Saleh, B. E. A. & Teich, M. C. Fundamentals of Photonics. (Wiley 2007).

  20. Zhang, P. et al. Cascaded fiber-optic Fabry-Perot interferometers with Vernier effect for highly sensitive measurement of axial strain and magnetic field. Optics Express 22, 19581 (2014).

    Article ADS Google Scholar

  21. Zhang, P. et al. Simplified Hollow-Core Fiber-Based Fabry-Perot Interferometer With Modified Vernier Effect for Highly Sensitive High-Temperature Measurement. IEEE Photonics Journal 7, 1–10 (2015).

    Google Scholar

  22. Dai, D. Highly sensitive digital optical sensor based on cascaded high-Q ring-resonators. Optics Express 17, 23817–23822 (2009).

    Article ADS CAS Google Scholar

  23. Claes, T., Bogaerts, W. & Bienstman, P. Experimental characterization of a silicon photonic biosensor consisting of two cascaded ring resonators based on the Vernier-effect and introduction of a curve fitting method for an improved detection limit. Optics Express 18, 22747 (2010).

    Article ADS CAS Google Scholar

  24. Troia, B., De Leonardis, F. & Passaro, V. M. N. Cascaded ring resonator and Mach-Zehnder interferometer with a Sagnac loop for Vernier-effect refractive index sensing. Sensors and Actuators B: Chemical 240, 76–89 (2017).

    Article CAS Google Scholar

  25. Flores, R., Janeiro, R., Dahlem, M. & Viegas, J. Environmental sensing with optical fiber sensors processed with focused ion beam and atomic layer deposition. in Proc. SPIE 9320, Microfluidics, BioMEMS, and Medical Microsystems XIII 932009, https://doi.org/10.1117/12.2080744 (2015).

  26. Janeiro, R., Flores, R., Dahal, P. & Viegas, J. Fabrication of a phase photon sieve on an optical fiber tip by focused ion beam nanomachining for improved fiber to silicon photonics waveguide light coupling. Optics Express 24, 11611 (2016).

    Article ADS CAS Google Scholar

  27. Kamikawachi, R. C. et al. Determination of thermo-optic coefficient in liquids with fiber Bragg grating refractometer. Optics Communications 281, 621–625 (2008).

    Article ADS CAS Google Scholar

Download references

Acknowledgements

This publication is based upon work supported by the Khalifa University of Science and Technology under Award No. CIRA-2018-110.

Author information

Authors and Affiliations

  1. Department of Electrical and Computer Engineering, Khalifa University of Science and Technology, Masdar City Campus, Abu Dhabi, United Arab Emirates

    Raquel Flores,Ricardo Janeiro&Jaime Viegas

Authors

  1. Raquel Flores

    View author publications

    You can also search for this author in PubMedGoogle Scholar

  2. Ricardo Janeiro

    View author publications

    You can also search for this author in PubMedGoogle Scholar

  3. Jaime Viegas

    View author publications

    You can also search for this author in PubMedGoogle Scholar

Contributions

R.F. and R.J. fabricated the devices and performed the experiments. R.F. designed the devices, carried out the data analysis and wrote the manuscript. J.V. supervised the work. All authors contributed to the discussion, interpreted the results, and reviewed the manuscript.

Corresponding author

Correspondence to Raquel Flores.

Ethics declarations

Competing Interests

The authors declare no competing interests.

Additional information

Publisher’s note: Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.

Reprints and permissions

About this article

Optical fibre Fabry-Pérot interferometer based on inline microcavities for salinity and temperature sensing (7)

Cite this article

Flores, R., Janeiro, R. & Viegas, J. Optical fibre Fabry-Pérot interferometer based on inline microcavities for salinity and temperature sensing. Sci Rep 9, 9556 (2019). https://doi.org/10.1038/s41598-019-45909-2

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1038/s41598-019-45909-2

Optical fibre Fabry-Pérot interferometer based on inline microcavities for salinity and temperature sensing (2024)

References

Top Articles
Latest Posts
Recommended Articles
Article information

Author: Aron Pacocha

Last Updated:

Views: 6223

Rating: 4.8 / 5 (48 voted)

Reviews: 95% of readers found this page helpful

Author information

Name: Aron Pacocha

Birthday: 1999-08-12

Address: 3808 Moen Corner, Gorczanyport, FL 67364-2074

Phone: +393457723392

Job: Retail Consultant

Hobby: Jewelry making, Cooking, Gaming, Reading, Juggling, Cabaret, Origami

Introduction: My name is Aron Pacocha, I am a happy, tasty, innocent, proud, talented, courageous, magnificent person who loves writing and wants to share my knowledge and understanding with you.